When closing the Application Manager > Node Properties window, it throws the below misleading error.
Please enter an integer between 1 and 2048.

Solution Steps:
The problem occurred as the user does not have access to the CONFIGURATION.INI file located under the C:\ProgramData\Wonderware\InTouch folder. To resolve this issue, Read\Write access needs to be provided for this file under the File Properties > Security tab.
_____________________________________________________________________________________________________


Recommended articles
[ISS Support Case] InTouch - Error
Today he's setting up the main server with the Historian. He has a backup of the database. He has a standalone app too. He imported the application and launched WindowMaker to convert it and it told him it requires 1920x1080 and says he has 1280x720 and he said no to convert. But when he says no it says the InTouch application is being edited in another session, cannot edit.